Select a controller to make it the active device for Dashboard, Inputs, Outputs, Health, Logs, and configuration pages.
Notifications are conditions you or your operator set, such as a high tank level or low pressure. They tell you when your chosen thresholds are reached.
Notifications are user-configured conditions based on scaled engineering values.
| Time | Type | Message |
|---|
Alerts are automatic warnings about system or equipment problems, such as an offline module, an out-of-range signal, or a relay feedback fault. This log includes both new alerts and cleared faults.
| Time | Type | Message |
|---|
Raw electrical ranges are assigned automatically from the signal type. All control, testing, notifications, charts and reports use scaled engineering values.
Build engineering signals from physical inputs and/or previously defined calculated values. Every enabled calculated signal is logged and charted automatically.
A-B (A+B)/2 A*B*0.001 sqrt(A*A+B*B) max(A,B)Changing modes forces the relay OFF. A manual ON/OFF command always takes authority and switches that relay to MANUAL.
Register field devices, deploy software updates, and run deployment checks without scrolling through one long page.
Commission one new Waveshare module at a time. This replaces the separate Module Configure Script and uses the controller's configured RS485 port and baud rate.
Ready.
Use this for IG502/controller Python applications. Upload a package once, then update one selected registered controller or all registered controllers. Remote controllers must be reachable over LAN/VPN and already support controller OTA.
No update staged.
Update the FieldLink customer website separately from controller software. This only replaces the public website files and does not modify pricing, accounts, controller configuration, logs, or Fleet data.
No website update staged.
Runs a complete software/read-only hardware health check before field deployment. Relay actuation remains OFF unless you explicitly select the bench-test checkbox. You can optionally include a real computer reboot test; after Windows/Linux returns, the DAQ will detect the reboot and automatically run post-reboot checks.
No deployment check run yet.
Artificial values are entered directly in scaled engineering units and pass through the same AUTO-control and alert logic as live measurements. Leave a field blank to clear its artificial value when you save.
| Time | Type | Message |
|---|
Owner-only master pricing catalog for the public FieldLink System Builder. Changes saved here become the source of truth for hardware, routed wire, connectivity plans, and sensor products.
Manage the information stored with your login. Your login username and access level are shown for reference.
Sign out of FieldLink on this browser.
Local controller hardware is shown independently so a failed module can be identified immediately.
Remote-node hardware will appear here as additional controllers and modules are deployed.
Reserved for solar, battery, charging, DC-bus, and off-grid power-system monitoring.
Field reliability status for the application, control loop, storage, communications, Fleet data integrity, and OTA recovery.
Generate a support package when troubleshooting a controller or Fleet issue.
Creates a support ZIP containing system health, recent system and audit logs, commissioning reports, software file hashes, watchdog/update status, database health, and a redacted configuration snapshot. Passwords, authentication records, session tokens, API keys, and known secret fields are excluded.
Records authenticated state-changing actions, logins, account changes, relay commands, configuration changes, and OTA actions.
| Time | Type | Message |
|---|
Choose which channels are active and which are shown in the normal operator UI. Hidden channels retain their configuration.
Owner always has full access. Admin, Operator, and Read Only role defaults are configurable below. Individual accounts can override their role for exceptions.
Devices and each Health section, log, and setup area have separate permissions below. Operator defaults allow real output control and notification editing. Read Only cannot operate outputs or edit rules. Owner always retains full access. Existing per-user overrides remain in effect.